ac6 dual voltage load bank

AC6 Dual Voltage for testing portable generators up to 6kW, 110V and 230V AC

Capacity
0-6kW in 333W switched steps of 333W. 666W, 3 x 1kW and 1 x 2kW, switched in any combination.

Test voltages
Two switch-selected voltage ranges: 220-240V, 1 phase 50/60Hz
110-120V, 1 phase 50/60Hz

Controls
Integral control panel with hinged weatherproof lid with:
1 – 48mm DIN voltmeter 0-300V linear
1 – 48mm DIN ammeter 0-100A linear
1 – 48mm DIN frequency meter 45-65Hz
1 – 3 position rotary switch 110V – OFF – 230V
2 – single pole MCB’s for protection
1 – meter fuse

Resistor Elements
Mica card elements wound with high-grade nickel-chrome stainless steel resistance tape with 600V primary insulation.

Cooling
Fan cooled with a single 170mm fan powered from the test load itself. The fan is mounted on one side of the load bank and blows horizontally through mesh screens on each side.

Input cables and connectors
Two 1.5m flexible input cables complete with colour coded input connectors to IEC-60309-2 are fitted as standard.

Case
All aluminium, finished in red powder coat, with instructions and warning labels. The load bank is fitted with a detachable cover with carrying handle and built-in cable stowage box.

Dimensions: 495 x 220 x 550mm high Weight: 12kg complete

AC6 Single Voltage for testing portable generators 6kW, 230V AC

ac6 load bank single voltageCapacity
0-6kW in 333W switched steps of 333W. 666W, 3 x 1kW and 1 x 2kW, switched in any combination.

Test voltages
220 - 240V, 1 phase 50/60Hz

Controls
Integral control panel with hinged weatherproof lid with:
1 – 48mm DIN voltmeter 0-300V linear
1 – 48mm DIN ammeter 0-100A linear
1 – 48mm DIN frequency meter 45-65Hz
1 – switching ON – OFF
1 – two pole MCB’s for protection
6 – on/off toggle switches
1 – meter fuse

Resistor Elements
Mica card elements wound with high-grade nickel-chrome stainless steel resistance tape with 600V primary insulation.

Cooling
Fan cooled with a single 170mm fan powered from the test load itself. The fan is mounted on one side of the load bank and blows horizontally through mesh screens on each side.

Input cables and connectors
One 1.5m flexible input cable complete
with colour coded input connector to IEC-
60309-2 is fitted as standard.

Case
All aluminium, finished in red powder coat,
with instructions and warning labels. The
load bank is fitted with a hinged cover with carrying
handle and built-in cable stowage box.

Dimensions: 495 x 220 x 415mm high Weight: 10kg complete

See the AC6 in action

Downloads: Cressall AC6 data sheet

Print page

Cressall Resistors Ltd, Evington Valley Road, Leicester, LE5 5LZ U.K. Tel: (+44) (0)116 273 3633