Capacity
0.6A to 600A at 30-50V DC, fully variable. Max 30kW. Sections of 0.6-5, 5, 10, 4 x 20, 100 and 2 x 200A
Controls
Integral control panel with:
Fixed sections: 9 illuminated toggle switches with DC contactors
Variable section: 1 knob to control graded rheostat
Indication: LED, ‘Power supply on’
Fuse: 1
Banana sockets: 2 x 4mm for output of shunt
Resistor Elements
Mica card elements wound with high-grade nickel-chrome stainless steel resistance tape with 750V primary insulation.
Cooling
Fan cooled with four 150mm fans powered from the test load itself. The fans are mounted under the load bank and blow vertically through mesh screens on each side.
Ammeter shunt
Rating: 100A = 100mV
Input cables and connectors
Two 2.5m 70mm2 flexible input cables complete with M12 lugs and quick-release connectors.
Case
All aluminium, finished in blue powder coat, with instructions and warning labels. The load bank is fitted with a carrying handle and two castors.
Dimensions: 560 x 400 x 840mm high Weight: 40kg complete
Download: Cressall DC600 load bank leaflet
Print Page
![]()
Cressall Resistors Ltd, Evington Valley Road, Leicester, LE5 5LZ U.K. Tel: (+44) (0)116 273 3633